Solar battery deep cycle VICTRON AGM 12V 286Ah (C100)

VICTRON Deep Cycle AGM 12V solar battery from 286AH C100 and 220Ah on C20.

It does not require maintenance and its use is ideal for refrigerator, water pumps, washing machine .. that is, appliances that have a motor. Since it supports very well the starting peaks of these devices without this affecting its useful life. Highly recommended for homes of seasonal use or weekend, that use this type of appliances.

* Technical support not included. Eligible separately here.

VICTRON AGM220
€660.66 
Tax included
In stock

 

Secure payment

 

Shipping policy

 

Return policy

VICTRON Deep Cycle AGM 12V solar battery from 286AH C100 and 220Ah on C20

Characteristics:
- Voltage: 12V.
- Measures: 229x138x227 mm.
- Weight: 20 Kg.
- Brand: VICTRON.
- Battery type: AGM.
- No maintenance.
- Capacity in C100: 286Ah and in C20: 220Ah.
- Separation plate between reinforced cells.
- Plates anchored to vibration and shock proof.
- AGM technology with absorbed electrolyte.
- Low self-discharge.
- Leaded battery terminals.
- Special alloy that ensures the corrosion resistance of the grids and the conductivity of the active material.
- Manufactured according to ISO 9002 certification and complying with CE and UL regulations.
- Fire resistant ABS material container.
- 2 years warranty.

Nominal capacity: discharge in 20h at 25 ° C
Dur. Floating life: 7-10 years at 20 ° C
Dur. Of life in cycles:
400 cycles at discharge 80%
600 cycles at discharge 50%
1500 cycles in discharge 30%

The batteries can be connected between them by forming three different types of connection:

 

Serial connection:

The serial connection is made when you want to increase the voltage while the capacity of the battery is maintained. To make this type of connection, you must attach the positive pole of one of the batteries, with the negative pole of the other.

Parallel connection:

The parallel connection serves to multiply the capacity of the battery while the voltage remains constant. To do this, all the positives are connected on one side and on the other side, all the negative poles.

Mixed serial and parallel connection:

This type of connection is made in installations at 24V where you want to connect more than 2 batteries at a time. In this case, batteries should always be placed in pairs, ie in pairs. It is not recommended to connect more than 8 12V batteries to each other, as this may damage the installation because of performance losses.

 


Attention: Never connect the positive and negative poles of the same battery together. This will result in a short circuit and irreparable damage to the battery. Also do not connect several batteries in a circle, for the same reason.
The most important cables of a solar installation are those that are used to connect the batteries to each other and the one that connects from the battery to the inverter. These cables must be sufficiently sectioned.